2-6-7-snyatie-i-ustanovka-vpusknogo-kollektora-s-toplivnojj-rampojj.html
2.6.7. Removal and installation of an inlet collector from a fuel stage
|
THE NOTE
To get access to atomizers, it is necessary to remove an inlet collector and a fuel stage together with заслонкой movings of a portion of fuel for management of air. (Depending on a variant the different quantity of working operations) can be demanded.
Necessarily replace consolidation of the chamber combustion (teflon) and a sealing ring.
|
Removal
Remove a protective cover of the engine.
Disconnect all necessary electric штекерные connections.
Remove from an inlet collector the vacuum hose which is passing between an inlet collector and the vacuum pump.
|
THE NOTE
This vacuum hose and the vacuum pump (it is located behind on a head of the block of cylinders) are established only in cars with an automatic transmission.
|
|
|
Fig. 2.73. The connecting union топливопровода
|
Disconnect топливопровод (following fuel collect and immediately close all open apertures) ( fig. 2.73).
Disconnect шланговые connections from a valve cover ( fig. 2.231).
Unscrew both screws 1 and 2 of a pipe of a cooling liquid ( fig. 2.231).
|
|
Fig. 2.232. Fastening screws маслопровода and pipes of a cooling liquid
|
Unscrew screws from маслопровода 1 and from a pipe of a cooling liquid 2 ( fig. 2.232).
Turn off both топливопровода on the high pressure pump.
Open clips of a hose and remove soaking up hose from the block of management throttle заслонки and from an inlet collector.
|
|
Fig. 2.233. Electric штекерное connection of the gauge of pressure of fuel
|
Disconnect electric штекерное connection 1 from the gauge of pressure of fuel ( fig. 2.233).
Remove probe for definition of level of oil and unscrew the screw 2 directing probeа oil level ( fig. 2.233).
Unscrew a fixing nut of a branch pipe of an inlet collector (if necessary also remove the block of management throttle заслонки).
|
|
Fig. 2.235. The screw of the holder of an inlet collector and directing probeа oil level
|
Separate in a separation place directing probeа level of oil 2 and turn off the screw of 1 holder of an inlet collector ( fig. 2.235).
Unscrew all screws of an inlet collector.
Cautiously remove an inlet collector together with a fuel stage from a head of the block of cylinders.
|
THE NOTE
Atomizers can remain in a fuel stage.
|
Installation
Installation is carried out in return sequence.
The inhaling moments
|