2-3-15-snyatie-i-ustanovka-klapana-1-sistemy-izmeneniya-faz-gazoraspredeleniya.html
2.3.15. Removal and installation of the valve of 1 system of change of phases timing
THE NOTE
And манжетные consolidations it is necessary to replace consolidations.
|
Removal
Disconnect an electric socket 1.
|
Fig. 2.140. An electric socket and the holder of a plait of wires
|
Turn off the holder of a plait of wires ( fig. 2.140).
THE NOTE
It is forbidden to take the valve of 1 system of change of phases timing for the tip.
|
|
Fig. 2.141. Fastening of the valve of system of change of phases timing
|
Turn off bolts and take the valve of 1 system of change of phases timing from the case ( fig. 2.141).
Installation
The new valve of 1 system of change of phases timing to get from packing follows directly ahead of installation.
THE NOTE
On the valve of 1 system of change of phases timing and in the case there should not be pollution.
|
ATTENTION
Protect the valve of 1 system of change of phases timing from physical influence (blows and pushes).
|
Moisten a sealing ring with engine oil.
Accurately insert the valve of 1 system of change of phases timing into the case and to press it by hand against the stop, it is horizontal concerning a valve axis.
Twist bolts and tighten them torque a key and a rattle 1/4 "with head TORX T20, and also Bithalter from the complete set of heads TORX.
The further installation and assemblage is carried out in return to sequence removal.
The inhaling moment
The valve of 1 adjustment of phases timing: 4 Нм.
|