   2-10-6-snyatie-i-ustanovka-kronshtejjna-dopolnitelnykh-agregatov.html 2.10.6. Removal and installation of an arm of additional unitsRemoval Disconnect a mass cable from АКБ at the switched off ignition. Merge cooling liquid. Result a radiator framework in service position. Remove полиwedge a belt. 
 
|  | Fig. 2.65. An electric socket of the gauge of level and oil temperature 
 | 
 Disconnect an electric socket on the gauge of level and oil temperatures (fig. 2.65 ).
 
|  | Fig. 2.67. Fastening of the compressor of the conditioner and штекерный a wire socket 
 | 
 Disconnect штекерный a  socket of 1 wire going to electromagnetic муфте  of the compressor of the conditioner (fig. 2.67 ).
 
| ATTENTION It is forbidden to open a contour of a central air of climatic installation. | 
 Turn off the compressor of the conditioner from an arm. 
 
| THE NOTE To avoid damages of lines and hoses of a contour of a central air, it is necessary to watch that lines and hoses have been laid without a tightness, excesses and breaks. | 
 Will hang out the compressor of the conditioner with the connected pipelines at the left on the car. Turn off an electric wire 1 from the generator. 
 
|  | Fig. 2.483. An electric wire and штекерное generator connection 
 | 
 Unscrew bolts. 
 
 
 
|  | Fig. 2.485. Fastening of a belt pulley of the pump of the hydraulic booster 
 | 
 Turn off ременный a  pulley of the pump of the hydraulic booster, thus ременный  it is necessary to hold a pulley about the help send  (fig. 2.485 ).
 
|  | Fig. 2.486. Fastening of the pump of the hydraulic booster 
 | 
 Turn off the pump of the hydraulic booster and to tie up aside, tubes remain connected (fig. 2.486 ).
 
|  | Fig. 2.479. Removal of a tension element semi wedge a belt 
 | 
 Unscrew a bolt and remove a tension element semi wedge a  belt (fig. 2.479 ).Disconnect a hose of system of cooling from a connecting branch pipe 2. 
 
 Unscrew bolts of 1 connecting branch pipe and remove a branch pipe with the thermostat 4 and a sealing ring of round section 3 (fig. 2.487 ).Remove a gear belt. Remove bypass a roller. 
 
|  | Fig. 2.488. Fastening of an arm of additional units 
 | 
 Unscrew bolts 1–6 and remove an arm of additional units (fig. 2.488 ).
 Installation Installation is made in return sequence. Check, whether on a place adjusting plugs at the upper right between an arm of auxiliary units and the block of cylinders. If is not present – insert. Tighten bolts in sequence 1–6: at first by hand, then with the certain moment of an inhaling. Establish a gear belt (adjust phases timing). Establish гаситель крутильных fluctuations. Establish a connecting branch pipe of the thermostat together with the thermostat. Establish a tension element semi wedge a belt. Establish the hydraulic booster pump. Establish the generator. Establish the conditioner compressor. Establish полиwedge a belt. Establish a framework of a radiator with hinged elements. Lower an emphasis of a forward support at the expense of a body weight on the rubber buffer and tighten nuts. Establish an overlay of a forward bumper. Connect the storage battery.  Fill in cooling liquid. 
 The inhaling moments Arm of additional units to the block of cylinders: 45 Нм. Bypass a roller of a gear belt to an arm additional агрегатов*: 40 Нм + 90  **. Emphasis of a forward support to a radiator framework: 28 Нм Shlangovye collars, width of 9 mm: 3 Нм. Shlangovye collars, width of 13 mm: 5,5 Нм. * Replace bolts. ** 90  correspond to one quarter of a complete revolution. 
 
 
 |